Cooling Towers are Bottle Type/ Square Type
in counter/cross flow design, ideal for large application with multiple cells.The maintenance of AEC Towers is very easy and cheaper than others. The towers can be installed at roof also.

  
 
 
 
 

Cooling Towers are designed for reducing the water temperature by using an air stream with minor evaporation to reuse precious water in process industry.

Fiber glass reinforced plastic ( FRP ) body in attractive looks.

Aesthetic, Compact Design and Light Weight.

The Tower is highly efficient and corrosion proof.

Designed and Constructed for minimum maintenance and long life.i.e., 400 % more than constructed tower.

Able to operate in aggressive environments and resistant to water borne contaminates.

The design is highly rigid against strong winds.

Uniform distribution of water by unique mechanism.

Honey Comb PVC Fill ( High efficiency fills) gives low pressure loss and thus economical to run.

Minimum drift loss of water.

The fan is specially designed to reduce noise.

HDG/ Epoxy coated steel hardware.

Inspection window for inspection in runnning position in case of square tower.

Capacity from 5 TR to 500 TR in sigle shell and above in multi shell.

 

 
Wooden Cooling Tower
R.C.C Cooling Tower
F.R.P. Counter Flow Type
F.R.P. / Fabricated Structure Cross Flow
  
DIMENSIONAL AND TECHNICAL DATA FOR FRP COOLING TOWER
MODEL NO.
NOMINAL CAP. (MTR)

MOTOR (HP)

HEAT REJECT K.Cal/HR X1000

OPERATING WEIGHT (KGS)

PUMP HEAD (MWC)

AEC-0991-SQ

2.5

0.25

9

50

1.5

AEC-1001-SQ

5

0.5

19

150

1.7

AEC-1001

5

0.5

19

150

1.7

AEC-1011

7.5

1

28

200

1.7

AEC-1021

10

1

38

260

2.0

AEC-1031

15

1

56

350

2.0

AEC-1041

20

1

75

420

2.5

AEC-1051

25

2

94

450

2.5

AEC-1061

30

2

115

500

2.6

AEC-1071

40

2

150

700

3.0

AEC-1081

50

2

190

800

3.0

AEC-1091

60

3

225

950

3.0

AEC-1101

70

3

260

1100

3.0

AEC-1111

80

5

300

1400

3.0

AEC-1121

90

5

340

1500

3.0

AEC-1131

100

5

375

1650

3.0

AEC-1141

120

7.5

450

1800

3.3

AEC-1151

150

7.5

565

1950

3.3

AEC-1161

175

7.5

655

2200

3.8

AEC-1171

200

10

750

2300

3.8

AEC-1181

250

10

940

3500

4.0

AEC-1191

300

10

1125

4000

4.0

AEC-1201

400

15

1500

6000

4.5

AEC-1211

500

15

1875

6500

4.5

AEC-1221

600

20

2250

7400

5.0



Normal TR capacity has been computed on the basis of water circulation rate of 4 USGPM/TR at 95.5-90-83 0F conditions.(1 USGPM=4.543 LPM)

All design specifications are subject to change without notice as company is constantly endeavouring to improve the performance of its Cooling Towers. The company reserve the right to make alterations from time to time.

Performance is based upon installation in an outdoor location and absence of near by structures, which might prevent free air movement.

All models are available in light pastel Green /Grey/ Blue colour normally to match environment, other colours can be made available on special request.



Copyright © 2007-2008, Alfacool Engineering Company.